Announcing AI-Native Market Access Product for Regulated Products

Learn More

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
MedTech regulatory leaders reviewing regulatory insights and intelligence on a laptop
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Webinars

eSTAR submissions overview and live Q&A with FDA

August 9, 2023

Webinars

From planning to acceptance - navigating submissions strategy and FDA market pathways for medical devices

July 20, 2023

Webinars

Regulatory AMA: EU MDR Transition Period Extension

June 29, 2023

Regulatory Briefs

An overview of 21 CFR Part 812: Investigational Device Exemptions (IDEs)

June 21, 2023

4 min read

‍

This document is a summary of the regulation and does include wording taken directly from the regulation itself. The original regulation should be referenced directly, however, for complete information when submitting an IDE request.

What is an investigational device exemption?

An investigational device exemption (IDE) allows a device to be used in a clinical study prior to obtaining market approval to collect safety and effectiveness data. Clinical studies are typically required to support a Premarket Authorization (PMA), but a small percentage of 510(k) applications also require clinical data when a predicate device comparison is inappropriate for the submission.  

Before a clinical study is initiated, an investigational device must have an approved IDE, unless it is exempt. Devices may be exempt from IDE requirements if they are noninvasive diagnostic devices, being used for consumer preference testing unrelated to device safety or efficacy, or intended solely for veterinary use or research with laboratory animals. Refer to the full text of 21 CFR 812 for details and additional exemptions.

Part 812 – General Provisions (Subpart A)

Scope

This regulation is applicable to all clinical investigations of devices used to determine safety and effectiveness, except where exempt.

Applicability

Abbreviated Requirements

Investigations are considered automatically approved for IDEs if the device is not considered a significant risk, unless the FDA has specifically notified the sponsor otherwise. In these cases, the sponsor must still obtain IRB approval for the investigation and must comply with other requirements of Part 812, including proper labeling, record keeping, and conformed consent requirements.

Exempted investigations

IDEs are not required for devices that fall into one of the following categories:

  • Devices that were in commercial distribution prior to May 28, 1976 that were used or investigated according to requirements in effect at that time. Devices that were introduced after May 28, 1976 but which have been found to be substantially equivalent to devices introduced earlier may also be exempt. This exemption is limited for Class II and III devices from the date an FDA regulation or order calls for the submission of a PMA (in the case of an unapproved Class III device) or establishes a performance standard for a Class II device.
  • Diagnostic devices for which the testing is noninvasive and without significant risk, and is not used as a diagnostic procedure without confirmation through another product or procedure.
  • Devices undergoing consumer preference testing, or testing of a device modification or combination of already distributed devices, if the testing is not for purposes of determining safety or efficacy and does not put subjects at risk.
  • Devices solely for veterinary use.
  • Devices intended for research on or with laboratory animals.
  • A custom device that is not being used to determine safety or efficacy for commercial distribution.

Definitions

21 CFR Part 812.3 provides definitions for many terms, some of which are listed here.

Institution: A person, other than an individual, who engages in the conduct of research on subjects or in the delivery of medical services to individuals as a primary activity or as an adjunct to providing residential or custodial care to humans. For example, a hospital, retirement home, confinement facility, academic establishment, and device manufacturer. The term has the same meaning as “facility.”

Institutional Review Board (IRB): Any board, committee, or other group formally designated by an institution to review biomedical research involving subjects and established, operated, and functioning in conformance with part 56. The term has the same meaning as “institutional review committee.”

Investigational device: A device, including a transitional device, that is the object of an investigation.

Investigator. An individual who actually conducts a clinical investigation, i.e., under whose immediate direction the test article is administered or dispensed to, or used involving, a subject, or, in the event of an investigation conducted by a team of individuals, is the responsible leader of that team.  

Monitor: When used as a noun, this term means an individual designated by a sponsor or contract research organization to oversee the progress of an investigation. The monitor may be an employee of a sponsor or a consultant to the sponsor, or an employee of or consultant to a contract research organization. Monitor, when used as a verb, means to oversee an investigation.  

Significant risk device means an investigational device that:  

  • Is intended as an implant and presents a potential for serious risk to the health, safety, or welfare of a subject;  
  • Is purported or represented to be for a use in supporting or sustaining human life and presents a potential for serious risk to the health, safety, or welfare of a subject;  
  • Is for a use of substantial importance in diagnosing, curing, mitigating, or treating disease, or otherwise preventing impairment of human health and presents a potential for serious risk to the health, safety, or welfare of a subject; or  
  • Otherwise presents a potential for serious risk to the health, safety, or welfare of a subject.  

Sponsor: A person who initiates, but who does not actually conduct the investigation, that is, the investigational device is administered, dispensed, or used under the immediate direction of another individual. A person other than an individual that uses one or more of its own employees to conduct an investigation that it has initiated is a sponsor, not a sponsor-investigator, and the employees are investigators.  

Sponsor-investigator: An individual who both initiates and actually conducts, alone or with others, an investigation, that is, under whose immediate direction the investigational device is administered, dispensed, or used. The term does not include any person other than an individual. The obligations of a sponsor-investigator under this part include those of an investigator and those of a sponsor.  

Subject: A human who participates in an investigation, either as an individual on whom or on whose specimen an investigational device is used or as a control.  

Labeling of investigational devices

An investigational device or its packaging requires a label with the following information:

  • Name and place of business of the manufacturer, packer, or distributor (per 801.1).
  • Quantity of contents.
  • Statement: “CAUTION—Investigational device. Limited by Federal (or United States) law to investigational use.”
  • Any additional relevant contraindications, hazards, adverse effects, interfering substances or devices, warnings, and precautions.
  • If used for animal research, a statement of “CAUTION—Device for investigational use in laboratory animals or other tests that do not involve human subjects” must be on the label.

IDE Labeling cannot have any statement that is false or misleading and cannot represent the device as safe nor effective.  

Prohibition of promotion and other practices

An investigational device is intended for use only within an investigation. Therefore, until a device is approved for commercial distribution by the FDA, the sponsor or investigator (or those working on their behalf) cannot:

To continue reading this Regulatory Brief, please download the full document here.

Data Sheets

Medtech quality management systems: an infographic

June 16, 2023

Webinars

Optimizing Regulatory Communication

June 14, 2023

Blogs

Regulatory information management (RIM) systems and organizational change management

By

Michael Peach

October 21, 2021

4 min read

At first glance, the juxtaposition of RIM and change management seems a little strange. One is a software tool and the other a management discipline, but one of the things we’ve seen across RIM deployments is that it’s difficult to have one without the other. For many regulatory affairs teams, a RIM system isn’t simply a tool, it’s a digital transformation. This means that there’s a broader set of organizational considerations and actions that need to surround the implementation of a RIM system to ensure its success. Remember that 70% of digital transformation initiatives fail.

RIM systems are a disruptive technology

Disruptive? Really? Aren’t RIM systems supposed to streamline regulatory activities, and improve team productivity? Yes they definitely provide these benefits, but they also require a change in how the team works. Most RIM implementations aren’t replacing existing software, they’re replacing manual processes. In our experience, Rimsys is displacing registrations that are managed via spreadsheets, and sometimes even paper-based processes.

This means that the way that teams have managed processes is changing significantly. While it’s likely that teams are struggling to operate effectively (there’s usually some organizational pain that leads to a RIM evaluation), there’s also discomfort with the change. RA team members are proficient in their work, they know how to get things done, and likely have systems they’ve created to cope with the inefficiencies in their current processes.

Regardless of department or industry, automation initiatives can lead to employees feeling threatened with obsolescence, lacking direction, and afraid of being replaced. In medtech regulatory affairs this is rarely the case. Most companies have to invest heavily in external consultants just to keep pace with the current workload. In fact, large medtech companies regularly outsource 50% or more of their regulatory activities. This doesn’t mean that team members won’t experience these insecurities. That’s why it’s important to have a change management strategy in place to support any RIM rollout.

A RIM change management strategy

All of these factors mean that RIM implementation that doesn’t have an accompanying change management strategy won’t see the same level of success, or deliver on expected outcomes. The good news is that there are a universal set of tactics to support effective change management that can be easily applied in this scenario. Here are 4 steps that you can take to lay the groundwork for a successful RIM implementation.

Step 1: start at the top

Teams that are in the process of acquiring a RIM system likely already have leadership support, but it’s important that your senior leaders have a visible presence in the process. This means issuing communications, participating in kick-off meetings, and being available to answer questions. This applies both to RA leaders and those in adjacent departments like QA and IT as well.

The visible support reinforces the idea that leadership teams are aligned and fully supportive of the changes taking place. It affirms that RIM is a strategic priority for the company, and helps to alleviate any fear or anxiety about the change. Leadership support also helps to signal to teams that they’ll be supported as they go through the implementation process, and that work will be prioritized.

Step 2: communicate early and often

RA teams are busy—often very busy. This is typically why a RIM system is being implemented in the first place. However, when teams are really busy, it’s really easy for communications to fall through the cracks. This means that plans and timelines for a RIM implementation need to be communicated more than once.

Communications should emanate from leadership teams (see step 1), and be candid about coming changes, the reasons for them, and the expectations from team members as the project moves forward. Leaders should encourage communication that moves in both directions, and be open to feedback from team members. Companies should look to create channels for RA team members to reach out with any comments or concerns.

Step 3: strive to minimize disruption

While there’s no way to completely eliminate the disruption associated with a new RIM system—it will fundamentally change the way a RA team works there’s no way around it—there are ways to minimize disruption. There first part of this is making sure you’re communicating enough about the project (see step 2). Team members are much more receptive to change if they aren’t blindsided by it.

It’s also helpful to take steps to make sure that team members have an opportunity to learn about the RIM systems throughout the acquisition and implementation process. Bring team members into product demonstrations, and let them ask questions about solutions that are being evaluated. Don’t wait to run training sessions until the RIM system is fully implemented. These can run in parallel. With this approach the whole team feels invested in the solution, and is fully ramped to start running at the end of implementation.

Step 4: lay the groundwork for continuous improvement

This article discusses change management from the perspective of a discrete event—the acquisition and implementation of a RIM system. However, RA teams shouldn’t look at change as something with fixed start and end, but rather as something continuous. RIM systems today represent one way that RA teams can embrace digitization and automation to improve how they work. There will be many additional opportunities as regulations, regulatory bodies, and technology evolve.

In recent years we’ve seen an expansion of UDI requirements for medical devices across markets. We’ve seen more stringent requirements for post-market surveillance. And we’ve seen the growing adoption of digital pathways for regulatory submissions and other interactions with health authorities. For many teams, a successful RIM implementation is just the first step on what will be a broader organizational transformation.

Successful changes for RIM and beyond

RIM systems can provide enormous benefits to RA teams, but only if they’re fully implemented and adopted. While deep in the weeds of requirements gathering and vendor evaluations it’s easy to overlook the fact that moving from traditionally manual processes to automated ones in a RIM system represents a significant organizational change. As a part of any RIM acquisition initiative, teams should fully understand their change management needs, and take steps to address them in concert with software selection.

Having teams fully onboard and supportive of the initiative makes them much more likely to adopt the final solution. Engaging in this way also allows you to plan for, and prioritize the resources needed for the implementation phase—leading to faster time to value for the project. Ultimately organizational change will and should be something that RA teams are comfortable with. The practices adopted with a RIM implementation can be used to support future digitization and automation across all RA activities.

To learn more best practices around RIM sourcing and implementation including an organizational self-assessment, detailed overview of capabilities, and a worksheet you can use for vendor evaluations, check out our RIM Buyer’s Guide for MedTech Companies.

RIM
Blogs

A primer on medical device classification

By

Bethaney Lentz

October 11, 2021

4 min read

While it may seem simple, medical device classification can be a challenging task for many medical device and IVD manufacturers. Device classes for specific regions and countries have a number of small variations, and each of those variations can impact the process by which a device obtains market clearance. Getting it wrong can lead to delays in getting to market. This article explores the classification systems for three major markets, and their associated regulations.

An important component of achieving regulatory approval is the appropriate classification of a medical device or in vitro diagnostic device, according to the specific regulations within a country or region. Product classifications are related to the intended use of the product and the perceived risk that it poses to a patient using the device. While this general approach is pretty standard across all regions, there are many small variations in different country classification systems that can impact how a device is regulated. It would be much easier if there was one global classification system that everyone followed.

However, since there are different guidelines to classifying a medical device (per country), we’ll dig into the most popular classification systems—Canada, the European Union and the United States. These three are globally perceived to have strong, thorough, and trusted quality and regulatory systems. Their approaches are often mirrored or used as proxies for market clearance in other countries.

Medical device classes

Canada

The Canadian Medical Devices Regulations include guidelines that classify devices into four risk classes. If a medical device can be classified into more than one class, the class representing the higher risk always applies.

  • Class I devices do not require a medical device licence to be sold in Canada, but manufacturers, distributors and importers of these devices are required to obtain an establishment licence.
  • Class II requires a medical device licence
  • Class III requires a medical device licence
  • Class IV requires a medical device licence

Some examples of different classes of devices in Canada include:

Class I Class II Class III Class IV
bandages, adhesive strips, crutches, canes powered toothbrush, hearing aids hip implants, respirators artificial heart, pacemaker

European Union

One of the main changes introduced with the new MDR/IVDR regulations are new classification rules for medical devices and in vitro diagnostic devices. If you have gone through the process of getting your medical device in the European market before, you might find it more difficult with the new EU MDR rules. For example, a new medical device you want to bring to market might now fall into a higher classification than it would have previously (under the MDD), and therefore require more testing, updates to documents, quality approvals, etc.

The new EU MDR brings the classification of medical devices in Europe more in line with international regulations, specifically the United States. These updated rules are listed in MDR 2017/745 for devices and IVDR 2017/746 for in vitro diagnostic products. As with Canada, if a medical device can be classified into more than one class, the class representing the higher risk always applies.

The EU has recently released a new guidance document MCDG 2021-24 to assist device manufacturers with device classification questions.

Class I – this classification is for the lowest risk device. Most medical devices in this category do not require a conformity assessment from a Notified Body so instead, they can be self-assessed. However, manufacturers must still complete a Technical File as part of the approval process.According to MDCG 2019-15, there are three subclasses under Class I. Unlike most Class I devices, these will require the involvement of a Notified Body.

  • Class Im: a product with a measuring function
  • Class Is: a product that is sterile
  • Class Ir: a product that is a reusable, surgical instrument

Class IIa – this classification is for a medium risk device. A conformity assessment by a Notified Body is required for this classification.

Class IIb – this classification is for medium-to-high risk devices. A conformity assessment by a Notified Body is required for this classification.

Class III – this classification is for the highest risk devices. A conformity assessment by a Notified Body is required for this classification.

Examples of different classes of devices in the European Union include:

Class I Class IIa Class IIb Class III
wheelchair, stethoscope, reading glasses surgical clamp, dental fillings, tracheostomy tube bone fixation plate, lung ventilator heart valve, simulator

In Vitro Diagnostic Devices:

Class A – this classification is for the lowest risk in vitro diagnostic devices. Most IVD devices in this category do not require a conformity assessment. Instead, they can be self-assessed.

Class B – this classification is for medium risk in vitro diagnostic devices. A conformity assessment by a Notified Body is required for this classification.

Class C – this classification is for medium-to-high risk in vitro diagnostic devices. A conformity assessment by a Notified Body is required for this classification.

Class D – this classification is for the highest risk in vitro diagnostic devices. A conformity assessment by a Notified Body is required for this classification.

Examples of the different in vitro diagnostic device classes in the European Union include:

Class A Class B Class C Class D
specimen receptacles, cynical chemistry analyzers pregnancy self-test, cholesterol self-test PSA screening, blood glucose self-test HIV blood diagnostic test, ABO blood grouping

United States

In the United States, the Food and Drug Administration (FDA) is responsible for overseeing the safety of medical devices. The FDA has established classifications for approximately 1,700 different types of devices and grouped them into 16 medical specialties referred to as panels. All three classes of devices are subject to General Controls which are the baseline requirements of the Food, Drug and Cosmetic (FD&C) Act.

  • Class I – General Controls (with or without exemptions)
  • Class II – General Controls and Special Controls (with or without exemptions)
  • Class III – General Controls, Special Controls and Premarket Approval

You are permitted to classify your own medical device based upon the FDA guidance documents and set regulations. However, if you wish for the FDA to assist with establishing your classification you can submit a 513(g) Request for Information. Note that there is a user fee associated with a 513(g) Request.

The device class determines which type of premarketing submission/application is required for market clearance.

In some instances, you do have the opportunity to reclassify your product after it’s been released to the market. The regulatory class of a device type, as defined by the Federal Food, Drug and Cosmetic Act (FD&C Act), may be changed through petition to the FDA. This process is only applied to a device type though, not to an individual device.

Examples of medical device classification in the US include:

Class I Class II Class III
tongue depressor, oxygen mask, adhesive bandage catheters, contact lenses, ultrasound equipment coronary stent, defibrillator orthopedic implant

Getting classification correct

Medical device classification is simple in that each country and region generally follows the same classification approach, and complex in that minor differences can change how a device is classified across markets. Understanding how a device is classified is one of the critical first steps regulatory affairs teams need to take when entering a new market, as medical device class often determines the pathway to market.

For example, in the EU classification can mean the difference between self-certification and a required conformity assessment from a Notified Body. In the US, classification can mean the difference between a 510(k) or PMA process for market clearance. Getting classification correct can ensure a smoother and faster route to market.

To learn more about market clearance processes for medical devices in the US, check out the Beginner’s Guide to the 510(k).

MedTech
Blogs

MDSAP - the ultimate guide to the medical device single audit program

By

Bethaney Lentz

September 20, 2021

4 min read

This article is an excerpt from The ultimate guide to the medical device single audit program (MDSAP) ebook.

Table of contents

What is MDSAP?

The Medical Device Single Audit Program (MDSAP) was designed and developed to allow a single audit of a medical device manufacturer to be applied to all country markets whose regulatory authorities are members of the program. The MDSAP provides efficient and thorough coverage of the standard requirements for medical device manufacturer quality management systems, and requirements for regulatory purposes (ISO 13485:2016). In addition, there are specific requirements of each medical device regulatory authority participating in the MDSAP that must be met:

  • Conformity Assessment Procedures of the Australian Therapeutic Goods (Medical Devices) Regulations (TG(MD)R Sch3)
  • Brazilian Good Manufacturing Practices (RDC ANVISA 16)
  • Medical Device Regulations of Health Canada (ISO 13485:2003)
  • Japan Ordinance on Standards for Manufacturing Control and Quality Control of Medical Devices and In Vitro Diagnostic Reagents (MHLW Ministerial Ordinance No 169)
  • Quality System Regulation (21 CFR Part 820), and specific requirements of medical device regulatory authorities participating in the MDSAP program.

This means that a report from a single MDSAP audit of a medical device manufacturer would be accepted as a substitute for routine inspections by all the member Regulatory Authorities (RAs) across the world. There are currently five participating Regulatory Authorities (RA) representing the following countries: Australia, Brazil, Canada, Japan and the USA.

In April, 2021, the RAs released an “Audit Approach” document (MDSAP AU P0002.006) that combines the formerly separate MDSAP Audit Model and Process Companion documents into a single guidance document. It includes guidance for assessing the conformity of each process and includes an audit sequence, instructions for auditing each specific process, and identifies links that highlight the interactions between the processes.

History of MDSAP

In March 2012 the US FDA announced that they had approved a final pilot guidance document “Guidance for Industry, Third Parties and Food and Drug Administration Staff: Medical Device ISO 13485:2003 Voluntary Audit Report Submission Pilot Program.” This allowed the owner or operator of a medical device manufacturing facility to be removed from FDA’s routine inspection work plan for 1 year upon completing a ISO 13485:2003 audit. This guidance document went into effect in June 2012, and was intended as an interim measure while a single audit program was being developed.

This pilot program was not very successful and few companies signed up because they did not see any advantage in participating. The manufacturer had to pay for a third party to inspect their facilities, generate a report, and share the inspection results back to the FDA. Many companies were reluctant to contract “someone else” to perform their inspection when they could easily wait for the FDA to conduct an inspection for free.

During its inaugural meeting in Singapore in 2012, the International Medical Device Regulators Forum (IMDRF) appointed a working group to develop a set of documents for a harmonized third-party auditor system. Hence, the “Medical Device Single Audit Program” (MDSAP) was formed. The concept was similar to the FDA’s original idea of creating a third-party auditor to help reduce their workload of performing regulatory audits of medical device manufacturers’ quality management systems. This new approach would consist of a single audit that would review regulatory QMS compliance, conducted by a third-party, who would later be called an Auditing Organization (AO).

From January 2014 to December 2016, five countries participated in a Medical Device Single Audit Program Pilot. In June 2017, a report was generated summarizing the outcomes of prospective “proof- of-concept” criteria established to confirm the success of the program. The outcomes are documented in the final MDSAP Pilot Report and recommended that the program become fully active and open to any manufacturer who requested this type of audit.

2012 Jan: Initiation of the pre-pilot project
2014 Jan: Announcement of the MDSAP Pilot project
Aug: Mid-Pilot Report
2015 Nov: 1st GMP Certificate delivered by ANVISA, using MDSAP audit report
Dec: Health Canada publish transition plan to replace CMDCAS by MDSAP
2016 Jan: 1st Canadian device license supported by an MDSAP certificate
Dec: Review of MDSAP Pilot project
2017 Jan: Auditing Organizations other than CMDCAS registrars can apply
July: Final Pilot Report concludes that the plan objectives met performance targets
2019 Jan: MDSAP replaces CMDCAS
2020 Implementation

Who is responsible for the MDSAP?

The governing body of the MDSAP is the Regulatory Authority Council (RAC), which is composed of two senior managers (and a few other staff members) from each participating RA. They are responsible for executive planning, strategic priorities, setting policy, and making decisions on behalf of the MDSAP International Consortium. The RAC also reviews and approves documents, procedures, work instructions, and more. The mission of the MDSAP International Consortium is to jointly leverage regulatory resources to manage an efficient, effective, and sustainable single audit program focused on the oversight of medical device manufacturers on a global scale.

Other international partners that are involved in the MDSAP include:

MDSAP Observers:

  • European Union (EU)
  • United Kingdom’s Medicines and Healthcare products Regulatory Agency (MHRA)
  • The World Health Organization (WHO) Prequalification of In Vitro Diagnostics (IVDs) Program

MDSAP Affiliate Members:

  • Argentina’s National Administration of Drugs, Foods and Medical Devices (ANMAT)
  • Republic of Korea’s Ministry of Food and Drug Safety
  • Singapore’s Health Sciences Authority (HSA)

The observers and affiliate members are not the same as the participating member RA’s. The observers simply observe and/or contribute to RAC activities. Affiliate members, on the other hand, are interested in engaging in the MDSAP program and are subject to certain rules. They are only given access to a certain level of information about the manufacturers, audit dates, and information in audit reports.

They are also invited to attend sessions that are open to members, observers, and affiliates only.

Audits can also be conducted by MDSAP participating RAs at any time and for various reasons including:

  • "For Cause" due to information obtained by the regulatory authority
  • as a follow up to findings from a previous audit
  • to confirm the effective implementation of the MDSAP requirements

The purpose of audits conducted by the RAs is to ensure appropriate oversight of the AOs MDSAP auditing activities. The AOs are appointed by the RAs and a list of the currently approved AO’s is published on the FDA website. Most AOs offer a broad range of management system certification services, beyond just medical devices. Manufacturers should verify that prospective AOs are clearly trained and perform MDSAP audits of medical devices.

AOs have the final word as to whether a manufacturer has met the requirements for the MDSAP during the execution of the audit and generation of the associated reports summarizing the results. MSDAP RAC participating RAs have the final decision regarding all development, implementation, maintenance, and expansion activities associated with the program.

Although an unannounced visit by an AO is rare, it can happen in circumstances where high-grade nonconformities have been detected.

How does an MDSAP audit work?

To continue reading this eBook including a detailed look at the MDSAP audit process and grading, pros and cons of the approach, and how to get started please register to download the full version.

MedTech
Blogs

Rimsys joins MedTech Europe

By

James Gianoutsos

September 10, 2021

4 min read

This week Rimsys became an associate member of MedTech Europe, the European trade association representing the medtech industry, alongside some of the world’s largest medical technology companies. As a member of the organization, we’ll have visibility into regulatory changes across the region as they’re being formed, and the opportunity to shape how those regulations are implemented. This access will help us to ensure that the digitization and automation of regulatory processes remains in reach for all medtech companies, and that our software will be best positioned to help them.

What is MedTech Europe?

MedTech Europe is a trade association focused on making innovative medical technology available to more people, and making healthcare systems more sustainable. Members of the organization include medical technology companies—device and in vitro diagnostic manufacturers, industry service and technology providers, and country-level associations within the European region.

The organization serves as a trusted resource of medical technology information for the public, providing data and highlighting the value of new technologies, and for policy-makers and other key stakeholders. It publishes industry research and statistics, contributes to health-related policy and legislation, and works to expand patient and provider access to new, lifesaving technologies.

Why did we join?

At Rimsys, we’re passionate about the medical technology industry, and focused on providing technology solutions to help medtech companies strengthen regulatory compliance, and bring new products to market more quickly. The European region is a focal point for medical technology regulation, and the MDR/IVDR regulations that began to take effect this year will inform the approaches of health authorities around the world.

Regulatory digitization and automation happens both at the manufacturer level and the health authority level. MDR/IVDR brings unique device identification (UDI) requirements, and a centralized technology system for product and post market surveillance information (EUDAMED) to the market. Both of these elements are digital by nature, and can serve as end-points of automated processes run within the Rimsys Platform.

Earlier this year, we introduced a new approach to UDI, one that ties together market requirements, product information, registrations, and selling status in an integrated regulatory lifecycle. Rather than managing UDI data separately from other regulatory information and activities, companies can auto-populate compliant UDI information directly, and will soon be able to submit that information electronically to the EUDAMED database. As a MedTech Europe member, we can participate in working groups around these systems, and ensure that we have the insights and access that we need to develop and deliver features like this for our customers.

How does this benefit our customers?

For Rimsys customers, this is all about maximizing the value they can get from our holistic Regulatory Information Management (RIM) platform. Our platform is designed to support a wide range of regulatory processes, and many of these processes are shaped by the regulations themselves. As members of MedTech Europe, we’ll be involved in policy discussions as they happen, and can ensure that the updates we make and features that we add are in alignment with the latest regulations. Understanding how regional policy is evolving also allows us to share that intelligence in-product—alerting customers to relevant changes, and updating market entrance requirements.

The second key benefit is access. The automation of regulatory processes is most effective when it can be done end to end. This therefore includes interactions with health authorities. Government agencies, including the European Commission, are establishing digital channels for product registration, UDI, and clinical and post market surveillance data. Our goal at Rimsys is to provide as many direct integrations with these systems as possible. As MedTech Europe members, we’ll be part of the groups that advise policy-makers, and help to develop these systems. As a result, we can help to ensure that our integrations are as functional and effective as possible.

Learn more about automation and digitization for regulatory affairs

Whether you distribute medical products in the European Union or in other markets, there can be significant benefits associated with digitizing and automating regulatory processes including better information access, more cross-company collaboration, less manual administrative work, and faster time to market for new products. To learn some more, see the Top 6 Benefits of a RIM system, or contact us to request a custom demo.

Company
Blogs

FDA 510(k) - a beginner's guide

By

Michael Peach

September 7, 2021

4 min read

This article is an excerpt from The beginner's guide to the 510(k) ebook.

Table of Contents

Introduction

Congratulations! You have successfully developed a new medical device. Now you need to take it to market. In the United States, this often means submitting a 510(k). A 510(k) is a structured package of information about your device and its performance and safety that you submit to the Food and Drug Administration (FDA) for “clearance” before you can sell your device in the U.S. In order to receive clearance from the FDA, your 510(k) will need to demonstrate that your medical device is substantially equivalent to another legally marketed device (called a predicate device). The substantial equivalence approval process is a simple equation that looks something like this:

The 510(k) is generally the most efficient route to market clearance in the U.S. because you show your device is safe and effective based on this substantial equivalence standard, instead of needing to present more extensive clinical trial data.

There are three types of 510(k): Traditional, Abbreviated, and Special. This eBook will begin with a general overview of the 510(k) process, including its purpose and benefits. Next, we will explore the Traditional 510(k) and the sections and components required in depth. Finally, we will look at the Special and Abbreviated 510(k).

Chapter 1: 510(k) basics

FDA: background and device oversight

Before we explain what a 510(k) is let’s first talk generally about the FDA and device oversight. The FDA is the U.S. governmental agency responsible for overseeing medical devices, drugs, food, and tobacco products. When it comes to medical devices, the FDA’s mission is to “protect the public health by ensuring the safety, efficacy, and security of…medical devices.” At the same time, the FDA also has an interest in “advancing public health by helping to speed innovations.” In other words, the FDA’s goal is to make sure devices are safe and effective for public use, while also ensuring that devices have a quick and efficient path to market.

In order to achieve this balance of safety and efficiency, the FDA has three different levels of oversight depending on the risk level of the device: (1) exempt from premarket submission, (2) Premarket Notification, also known as 510(k), and (3) Premarket Approval (PMA).

When is a 510(k) required?

A 510(k) is required for medium risk devices that have a predicate on the market which can be used to demonstrate the safety and effectiveness of the new device. Meanwhile, a PMA is required for high-risk or novel devices which require a higher level of scrutiny to be confirmed safe and effective.

A 510(k) is not only required for new devices, but also for devices that have been modified in a way that could impact safety or effectiveness. This could include changes to the:

  • Design
  • Components
  • Materials
  • Chemical composition
  • Energy source
  • Manufacturing process
  • Intended use

You must submit your 510(k) at least 90 days before marketing the device.

What Exactly is Substantial Equivalence?

Now that we know what a 510(k) is, let’s talk about the substantial equivalence standard. You’ll recall from the introduction that your 510(k) must show that the new (or modified) device is substantially equivalent to at least one other legally marketed device, called a predicate device. Substantial equivalence looks at the intended use and the technological characteristics of the two devices.

More specifically, you must show:

  • that the new device has the same intended use as the predicate, and
  • the differences between the two devices do not raise questions about the safety and effectiveness of the new device.

Now let’s take a closer look at intended use and technological characteristics.

Intended use

Intended use means the general purpose or function of the device. The FDA will look at your proposed labelling and your Indications of Use section of the 510(k) to determine the intended use of your device (this is covered in Chapter 2). Intended use includes:

Technological characteristics

Once the FDA has determined that a predicate device exists and that the new device and the predicate device have the same intended use, it will move on to compare the technological characteristics. Technological characteristics include:

  • Materials
  • Design
  • Energy source
  • Other device features

The two devices do not have to be identical, and in fact they almost never are. The key here is to demonstrate that any differences do not have a significant impact on safety or effectiveness. Here’s what to cover when you compare your device’s technological characteristics with that of the predicate device:

Overall description of the device design

  • Engineering drawings or diagrams to explain the device and component parts.
  • List of component parts and explanation of how each component contributes to the overall use and function of the device.
  • Physical specifications: dimensions, weight, temperature, tolerances, etc.

Materials

  • Detailed chemical formulation used in all materials of constructions (especially those that come into contact with a patient).
  • Any additives, coatings, paint, or surface modifications.
  • How materials have been processed and what state they’re in.

Energy Sources

  • Use of batteries, electricity, etc.

Other technological features

  • Software/hardware
  • Features
  • Density
  • Porosity
  • Degradation characteristics
  • Nature of reagents
  • Principle of the assay method

In deciding whether the differences in technological characteristics impact safety or effectiveness, the FDA will typically rely on descriptive information about the technological characteristics as well as non-clinical and clinical performance data.

Let’s look at an example: A manufacturer submits a 510(k) for a new type of contact lens. Both the new device and the predicate device are indicated for daily wear for the treatment of astigmatism. The predicate device is only available in a clear lens, but the new device comes in a line of colors, including purple tinted lenses.

Who is responsible for submitting a 510(k)?

The following four types of organizations may be responsible for submitting a 510(k):

Manufacturers

  • End-of-line device manufacturers who will be placing a device on the U.S. market.
  • Note: Does not apply to component part manufacturers unless components will be marketed independently.

Specification developers

  • Companies that develop the specifications for a finished device which has been manufactured elsewhere

Repackers or relabelers

  • Required to submit a 510(k) if they significantly alter the labeling or condition of the device, including modification of manuals, changing the intended use, deleting or adding warnings, contraindications, sterilization status.
  • Note: This is rare. The manufacturer, not the repackager or labeler, is typically responsible for the 510(k) submission.

Importers

  • Importers that introduce a new device to the U.S. market may need to submit a 510(k), if it hasn’t already been submitted by the manufacturer.

Chapter 2: Contents of a Traditional 510(k)

Now that we’ve covered the basics, let’s explore what actually goes into your 510(k).

A Traditional 510(k) should contain all the following components in the list below. In some cases, a particular section may not apply to your device. When that happens, it’s a good idea to include the section anyway and just state “This section does not apply” or “N/A” under that heading.

  • Medical Device User Fee Cover Sheet (Form FDA 3601)
  • Center for Devices and Radiological Health (CDRH) Premarket Review Submission Cover Sheet (Form FDA 3514)
  • 510(k) Cover Letter
  • ...

To continue reading this eBook including a detailed walk-through of all the Traditional 510(k) components, submission requirements and timelines, and an overview of the other 510(k) forms including the Abbreviated 510(k) and the Special 510(k), please register to download the full version

MedTech
Blogs

EUDAMED and UDI in Europe: an overview

By

Michael Peach

August 17, 2021

4 min read

What is EUDAMED?

The European Databank on Medical Devices (EUDAMED) is an IT system developed by the European Commission to increase transparency and improve surveillance of medical devices (and in vitro diagnostics) that are sold within the European Union. It serves a key functional role in the unique device identification (UDI) requirements included in the MDR and IVDR regulations.

This article excerpts from The Ultimate Guide to the EU/IVDR UDI ebook to highlight the specific role and associated requirements that the EUDAMED database plays in the new regulations.

Element 4: The UDI database

The fourth component of the UDI system is entry of UDI and device information into the UDI database through EUDAMED. The MDR and IVDR require manufacturers to register all devices and submit specific information to the database before placing a device on the market. The core data elements provided through the UDI database will be accessible to the public free of charge. The list below outlines all of the required information for device registration.

Annex VI, Part A of 2017/745, states that the UDI database will contain all information about devices presently on the market and discontinued products. The database is designed to allow for linking across all packaging levels of the device. For all devices currently on the market, manufacturers are required to periodically verify the accuracy of the information in the database. If any changes are made to a device that do not require a new UDI-DI, manufacturers must still update the database within 30 days.

Information to be submitted with the device and economic operator registration must include

  • Economic operator information (2017/745 Annex VI, Part A(1)):
  • Information relating to the device
  • Manufacturing information

The tables below outline all of the specific information that must be submitted to EUDAMED:

Economic Operator information
  • Type of economic operator - manufacturer, authorized representative, importer, distributor, a person who sterilizes systems or procedure packs, an investigator for clinical investigations
  • Name, address, and contact details of the economic operator or of any person submitting information on behalf of the economic operator
  • Name, address, and contact details of person responsible for regulatory compliance
  • Presence of human blood, human plasma, tissues, or cells of human or animal origin
  • Single Identification Number of the clinical investigation

Information relating to the device
  • Information regarding the certificate issued by the notified body
  • Member State in which the device will be placed on the market, and for all class IIa, IIb, or III devices, all Member States where the device will be made available
  • Risk class of the device
  • Whether the device is single-use
  • Whether the device contains any substance which may independently be considered a medicinal product, and name of that substance
  • Presence of human blood, human plasma, tissues, or cells of human or animal origin
  • Single Identification Number of the clinical investigation
  • Whether the device is intended for any non-medical purpose
  • Summary of safety and clinical performance for any class III or implantable devices
  • Status of the device (on market, recalled, discontinued, field safety corrective action initiated)
  • Manufacturing informatione
  • Quantity per package configuration
  • Basic UDI-DI and any additional UDI-DIs
  • Production information including expiration date or manufacturing date, lot number, serial number
  • The unit of use UDI-DI, if applicable
  • Name and address of the manufacturer
  • The Single Registration Number (SRN)
  • Name and address of the authorized representative, if applicable
  • Medical device nomenclature code
  • Risk class of the device
  • The name or trade name of the device
  • Device model, reference, or catalogue number
  • Clinical size information, including volume, length, gauge, diameter
  • Additional product description, if applicable
  • Storage and/or handling conditions
  • Whether it is a single-use device
  • Maximum number of reuses allowed
  • Whether it is sterile
  • Need for sterilization before use
  • Containing latex
  • URL for any additional information
  • Critical warnings or contra-indications
  • In addition to this information, the European Commission recently released the UDI HelpDesk. The HelpDesk will provide support to economic operators in the implementation of the obligations and requirements introduced by the new UDI system.

    To learn more about EUDAMED and the European UDI system including a UDI overview, formats and issuing entities, implementation timelines, and key differences between the EU and US UDI systems, please register to download the full ebook.

    MedTech
    I agree to the privacy policy including to Rimsys using my contact details to contact me for marketing purposes.
    Thank you! Your submission has been received!
    Oops! Something went wrong while submitting the form.
    Hand holding smartphone showing email app with 12 unread messages notification.