Announcing AI-Native Market Access Product for Regulated Products

Learn More

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
MedTech regulatory leaders reviewing regulatory insights and intelligence on a laptop
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Webinars

Insights and actions from the 2023 medtech regulatory performance report

February 23, 2023

Webinars

The Impact of MDR transition period extensions

February 8, 2023

eBooks

2023 Regulatory performance report

February 1, 2023

4 min read

Today at Rimsys, we unveiled the 2023 MedTech Regulatory Performance Report, a new set of insights into the state of medtech regulatory affairs. Compiled based on interviews with 200 regulatory professionals and executives, the study provides a detailed look into how regulatory teams are staffed, their processes, the tools they use, and ultimately how they perform.

Why did we create this study? There were two driving factors behind the research. The first was a common theme that we heard from a number of our customers: Regulatory leaders don’t have clear data and benchmarks. They don’t necessarily know how long a new market submission should take, and how to plan for or assess the work of their teams. While other studies look at the medtech industry broadly or the state of the regulatory profession, this study tries to build a comprehensive resource for regulatory (and company) leaders.

The second factor was really for ourselves and the team at Rimsys. As a company building solutions specifically for medtech regulatory affairs, we wanted more insight into where companies were successful, where they struggled, and where we can add value.

What did we find? Regulatory teams perform a lot of hero work and rate themselves highly for their accomplishments. At the same time there is a lot of opportunity for process improvements, and companies that invest in digital transformation for regulatory affairs see better performance. ‍

Regulatory professionals are superheroes

Regulatory teams are generally pretty small. Most companies have less than 10 full-time regulatory professionals. These small teams complete an enormous amount of work. Last year on average, RA teams completed 50 license renewals, 50 license updates, and 10 new market submissions. This is impressive output.

Digging a bit under the covers, we found that this output relied heavily on the support of external consultants. 90% of companies use consultants to keep pace with their regulatory workload. Front-line employees also struggle with burnout. They were much more likely to report feeling under-resourced than regulatory leaders. ‍

But process problems persist

A lot of regulatory work remains extremely manual. 70% of regulatory teams spend half their time or more on repetitive administrative tasks.  All of this manual work increases the frequency of errors and required rework. 61% of companies reported a major non-compliance incident in the past 2 years.

Manual work also makes it difficult to complete regulatory projects in a timely fashion. Teams completed a lot of projects, but each took a long time. Over half of all companies spend 4 months or more on license renewals, license updates, and new market submissions.  ‍

Moving regulatory affairs forward

As regulatory requirements become more complex, there’s a natural question about how teams will work moving forward. MDR & IVDR in Europe have significantly increased the regulatory workload required to bring and keep products on the market. Will organizations be able to keep pace with the same resources, tools, and processes?  

No, and the performance report shows that medtech companies are investing to improve their regulatory capabilities. The majority of companies are planning to increase the sizes of their RA teams in 2023, and 40% expect to increase their investments in regulatory software. Companies are increasingly adopting specialized software to better support regulatory processes. ‍

Dig into the survey results

The full survey results provide insights into more aspects of regulatory performance. They show that companies need to take a deeper look into their processes and how regulatory resources are allocated. There are two ways to learn more:

  1. Visit the survey page to see the full results (the survey whitepaper can be downloaded at no cost)
  2. Watch the recording of our webinar with PA Consulting. We discuss the survey results in more detail and share our regulatory predictions for 2023

‍

Data Sheets

Making the case for a RIM system: an Infographic

December 15, 2022

Webinars

Medtech Post-market essentials

December 8, 2022

eBooks

Post-market surveillance for medical devices in the European Union

December 5, 2022

4 min read

This article is an excerpt from Post-market surveillance for medical device in the European Union.

Table of Contents

What is post-market surveillance?

Post-market surveillance (PMS) is designed to monitor the performance of a marketed medical device by collecting and analyzing field use data. Article 10 of the EU MDR and IVDR requires all device manufacturers to have a post-market surveillance system in place. The main elements of the PMS are laid out in Article 83, and additional details for lower-risk and higher-risk devices are covered in articles 84 and85, respectively.

In general, a PMS system consists of both proactive activities and reactive, or vigilance, activities. While post-market surveillance and vigilance are sometimes used interchangeably, vigilance consists of separate activities that feed post-market surveillance programs.

Post-market surveillance systems are used to collect and analyze data not only about the manufacturer’s device but also about related competitors’ devices that are on the market. Data collected through PMS procedures is then used to identify trends that may lead to, among other things, quality improvements, updates to user training and instructions for use, and identification of manufacturing issues.

Note that “market surveillance” encompasses activities performed by a Competent Authority to verify MDR compliance, and should not be confused with the topic of this ebook,“post-market surveillance," which is performed by the manufacturer.

What classes of medical devices require post-market surveillance?"

All medical devices marketed in the EU require some level of post-market surveillance, and all medical device manufacturers must implement a post-market surveillance system (PMS). The requirements of the PMS, however, vary and should be “proportionate to the risk class and appropriate for the type of device” (MDR Chapter VII). In particular, the type and frequency of reporting vary based on a device’s risk class.

Components of a successful post-market surveillance plan

A post-market surveillance plan (PMS) is an integral part of a manufacturer’s quality management system and provides a system for compiling and analyzing data that is relevant to product quality, performance, and safety throughout the entire lifetime of a device. The PMS should also provide methods for determining the need for and implementing any preventative and corrective actions. A PMS system should include and define:

Surveillance data sources

With the increased focus on proactive risk identification in the MDR, it is important to design post-market surveillance systems that actively acquire knowledge and detect potential risks. It is not sufficient to rely solely on spontaneous reporting by healthcare providers, patients, and other stakeholders.

Post-market surveillance plan components

In addition to information coming from Clinical Evaluation Reports and complaint and adverse event reporting, typical sources of surveillance data include:

• Social media networks: Because many of your stakeholders may be communicating on social media networks, it is important to employ social listening techniques and/or tools to identify issues and concerning trends as they develop.

• Industry and academic literature: Any studies, academic papers, and other literature that addresses similar devices or the specific use cases for which your device is designed should be evaluated. In particular, risk factors and adverse events identified with similar devices should be closely examined. It is also important to identify newer technologies that may affect the benefit-risk ratio and establish a new definition of “state of the art” for the device type.

• EUDAMED: While the European Database on Medical Devices (EUDAMED) is not yet fully functional, it is intended to provide a living picture of the lifecycle of all medical devices marketed in the EU. Manufacturers should take special care to consider information for similar devices made available through the EUDAMED system in the future.

• Registries: Patient, disease, and device registries can provide information that informs the clinical evaluation process which provides input into the post-market surveillance system.

Data analysis methodology

A well-defined data analysis methodology will accurately identify trends and lead to defendable decisions in the application of post-market experience. Once the necessary information has been identified and collected, and potentially cleaned of incomplete or otherwise unusable data, the data needs to be analyzed.

The goal is to identify meaningful trends, correlations, variations, and patterns that can lead to improvements in the safety and efficacy of the device. There are many data analysis tools available that can assist with:

• Regression analysis that will identify correlations between data (e.g. the device location/geography correlates to battery life).

• Data visualization that can be useful in spotting trends in the data.

• Predictive analytics, which can be particularly useful with large data sets, to identify future trends based on historical data.

• Data mining, which is also normally used with large datasets, to organize data and identify data groups for further analysis.

Benefit-risk indicators and thresholds

The MDR requires that medical device manufacturers not only demonstrate the clinical benefit of their device but also quantify the benefit-risk ratio. The benefit of a device must be shown to clearly outweigh the risk for it to gain market approval. Article 2 (24) of the MDR defines the benefit-risk determination as “the analysis of all assessments of benefit and risk of possible relevance for the use of the device for the intended purpose when used in accordance with the intended purpose given by the manufacturer.”

A PMS system should clearly define benefit-risk calculations and the data used to support them. Post-market surveillance activities are critical in order to re-evaluate and maintain the benefit-risk calculations and determinations of a device throughout its life. Information that is gained through a PMS system can lead to:

• Identification of new risk factors.

• Adjustments to risk frequency and/or severity values based on actual use data.

• Adjustments to established risk calculations based on new “state of the art” technologies becoming available.

• Adjustments to established benefit calculations based on actual use data.

Complaint and feedback handling processes

While complaint handling and other feedback tracking are more often described as part of post-market vigilance systems, they play a role in the more proactive post-market surveillance processes as well. A PMS system should define ...

To continue reading this ebook, download the full version.

Blogs

IMDRF: International Medical Device Regulatory Forum

By

Dell Lundy

October 14, 2022

4 min read

The medical device industry is vast and diverse, with each country or regional authority having its own regulatory body and requirements. For instance, medical devices are classified in ascending order in the United States, with Class I devices being the lowest risk class. Devices that pose the highest risk to users or patients and require the most regulatory oversight (pacemakers, defibrillators, etc.) are Class III devices, and devices that pose a moderate risk, such as syringes and catheters, are Class II devices. While this is a logical way to categorize medical devices, not every country uses this model. 

Medical device regulations will likely never be universally uniform. Still, there is a concerted effort on behalf of regulatory experts from some of the largest medical device markets in the world to harmonize regulations and regulatory best practices. The International Medical Device Regulatory Forum (IMDRF) is a body of medical device regulatory specialists from around the world working together to standardize regulations and “accelerate international medical device regulatory harmonization and convergence.” While the IMDRF isn’t a regulatory body, its guidelines are often adopted by its member countries and adapted to fit their regulations and initiatives. In this article, we’ll give you an overview of the IMDRF, including its history and how its work impacts the global medical device industry.

The IMDRF’s beginning

The IMDRF was conceived in 2011 when Australia, Brazil, Canada, China, the EU, Japan, the US, and the World Health Organization (WHO) met to discuss the formation of this forum. One of their main goals was to build on and expedite the work of the Global Harmonization Task Force (GHTF), the organization that laid the foundation for the IMDRF. 

The idea for the GHTF came from a meeting between representatives from the US, EU, Canada, and Japan in 1992. They met to discuss the possibility of forming a “consultative body” of regulatory specialists with the goal of “harmonizing medical device regulatory practices” worldwide. The GHTF held its first meeting in January 1993, forming study groups to evaluate different aspects of regulatory processes, including each member nation's quality management and Good Manufacturing Practices (GMPs). Today, the IMDRF continues to build on the strong foundation laid by the GHTF.

IMDRF members

As mentioned, the IMDRF works to harmonize medical device regulatory best practices worldwide. This mission requires the cooperation of regulators from many countries, performing in-depth studies and publishing guidelines that shape the global regulatory landscape. There are 11 members and their regulatory authorities that comprise the IMDRF:

IMDRF functions

The IMDRF is an international medical device regulatory body that offers guidance rather than implementing binding regulations, i.e., they don’t have the authority to mandate directives. According to the FDA, they “develop internationally agreed upon documents related to a wide variety of topics affecting medical devices.” Its members develop these documents by conducting studies via working groups, which we discuss in the next section.

IMDRF working groups

The IMDRF working groups are like subcommittees that focus on specific regulatory issues pertaining to medical devices. They address new technology, trends, and areas where harmonization of standards and regulations would be most beneficial. Their working groups conduct studies and research with the aim of providing regulatory best practices and universally applicable guidelines. There are currently seven active working groups:

There are various participants in every active working group, and these groups can also include regulatory bodies that aren’t IMDRF members. Through their sharing and collection of data, working groups gain valuable insights that enable them to create guidelines that IMDRF members can relatively and easily implement around their existing medical device regulations. This helps to ensure the safety and efficacy of medical devices while promoting the harmonization of regulatory best practices and standards. These documents serve to accelerate the convergence of medical device regulations around the globe and have produced 69 guidances to date.

The IMDRF might not be a regulatory body or have any binding authority, but they are well respected within the medical device community. Their guidance documents help to shape regulatory standards in the world’s largest medical device markets.  Staying abreast of IMDRF developments is a regulatory intelligence best practice (much like having a holistic regulatory information management system that provides structure for the medical device industry). Shameless plug aside, understanding the current undertakings of IMDRF working groups is a great way to better understand what’s going on in the medical device regulatory world and what changes might be coming down the road.

To learn more about the IMDRF, visit their website at imdrf.org.

‍

MedTech
Blogs

Ask Rimsys!

By

Wendy Levine

October 11, 2022

4 min read

At Rimsys, we pride ourselves on delivering tools that empower medical device regulatory affairs professionals to simplify and automate daily workflows, react quickly to changing regulations, and track product registrations around the globe. In order to deliver software that empowers RA teams to exceed regulatory campaign expectations, we not only need to understand current and changing global regulations; but we also work hard to understand what the community is talking about, what issues they are trying to solve, and what they would like to explore in more depth. 

So - we are asking for your input!

In order to address the topics that are of most interest to you, we’re launching our “Ask Rimsys” campaign. As part of this initiative, we invite you to submit your medical device regulatory questions to us - and once a week we’ll choose a question to answer either via direct social media response, a blog post, or even a short video response. Preference will be given to the following:

  • Questions with interest to the broader regulatory community (we will not be able to provide individual or company-specific consultation).
  • Questions which touch on regulatory workflows and best practices.
  • Questions dealing with the use of technology in optimizing regulatory activities.

If your question is selected, we’ll send you some Rimsys gifts - typically one of our highly requested “Regulatory Ducks in a Row” t-shirts featuring our too-cool for regulatory problems mascot, Reggie the Regulatory Duck. Look for random giveaways during the week too!

We’ll also be holding periodic “As us Anything” webinars with our regulatory team and other experts. These webinars will most often cover a broad topic, such as UDI, and we will take questions ahead of, and during, the webinars. Check out our events page for a list of upcoming webinars and recordings of past webinars.

As a company built by regulatory professionals, we understand the constant pressure on regulatory affairs professionals to stay on top of the changing regulatory landscape and improve your game. That’s why we’re committed to being a reliable friend and a source of relevant information - as well as a provider of world-class RIM software and services. So, help us focus on the issues most important to you by submitting your regulatory questions on Twitter by using #AskRimsys (and be sure to follow us) or answering our short 3-question survey.

And feel free to respond to any of questions or our responses with any regulatory insights you have as well. We look forward to hearing from you, and remember, #AskRimsys!

Company
Blogs

Introduction to Notified Bodies

By

Dell Lundy

October 4, 2022

4 min read

The medical device industry is vast, diverse, and heavily regulated, with different countries and regions having varying regulatory requirements and processes. The European Union (EU) is one of the largest markets in the world for medical devices, and if you intend to put a medical device on the market in the EU, there is a good chance you’ll have to work with a Notified Body. 

So, what is a Notified Body? In this brief blog post, we’ll discuss what Notified Bodies are, what they do, and how to work with one. 

What is a Notified Body?

Notified Bodies play the role of gatekeepers to the EU market for a majority of medical devices/in vitro diagnostics. Notified Bodies for medical devices are independent organizations appointed by EU member states to assess the conformity of certain products before they are placed on the market. Conformity assessments ensure that products are technically safe, compliant, correctly documented, and manufactured under the correct conditions as outlined by applicable legislation, primarily the EU MDR and IVDR in the case of medical devices. 

It’s important to note that not all Notified Bodies have the capability to perform assessments for all types of products. For instance, some Notified Bodies have been designated for MDR, meaning they can perform conformity assessments according to EU MDR 2017/745, Article 35, and others can provide conformity assessments for in vitro diagnostics (IVDs) in accordance with EU IVDR 2017/746, Article 32. It’s essential to make sure you work with the right Notified Body to get your medical device to the EU marketplace. 

What types of medical devices require a Notified Body?

Medical devices regulated under the MDR as Class IIa, Class IIb, or Class III devices require that a conformity assessment be performed by an accredited Notified Body before receiving a CE marking and being placed in the market. Some Class I devices also require an assessment by a Notified Body, including devices that are sterilized, have a measuring function, or are reusable surgical instruments. Other Class I devices can be self-assessed by the manufacturer. 

In vitro diagnostic (IVD) devices designated as Class B, Class C, or Class D also require a conformity assessment by a Notified Body. Only Class A IVDs can be self-assessed by the manufacturer.

What is the role of Notified Bodies under the EU MDR/IVDR?

All medical devices must have CE marking before they can enter the European market. One of the main roles of Notified Bodies is to provide conformity assessment on medical devices before granting them a CE marking, which is also known as a “European Passport,” as it allows products to move relatively freely throughout the EU. 

Notified Bodies provide conformity assessment during both the design and production phases of a product, ensuring that medical device manufacturers live up to the requirements of the MDR/IVDR. They audit manufacturing processes and conditions, quality management systems (QMS), and product specifications to make sure that they conform with EU regulations before being placed on the market. It’s also the role of the Notified Body to make sure the manufacturer has the infrastructure in place to market and provide post-market surveillance in the EU.

Notified Bodies provide conformity assessment in support of the EU MDR/IVDR General Safety and Performance Requirements (GSPR) but ultimately, it’s the manufacturer’s responsibility to ensure all requirements have been fulfilled. This includes choosing the right Notified Body to work with to get their medical device on the EU market. 

How do you choose the right Notified Body to work with?

It might surprise you to know that not all Notified Bodies are designated for both MDR and IVDR, meaning that it is critical that you do your due diligence to connect with the right Notified Body for your product. Notified Bodies are designated by the competent authority of EU member states to perform certain types of conformity assessments for certain types of medical devices and manufacturing processes/conditions. This means that the Notified Body you work with is largely dependent on the type and classification of your medical device as well as the type of conformity assessment process you want the Notified Body to perform. A list of accredited Notified Bodies is available in the EU NANDO database, which can be searched and filtered by country, specific legislation, and other technical competencies.

A lot rides on selecting the right Notified Body, so it’s imperative that you find the organization that best fits your company’s needs. Learn what you can about their processes, how they communicate with their clients, and even their submission templates and processes. Choose an organization whose standards and processes align with your company’s goals. 

According to Rimsys regulatory expert, Bruce McKean, when it comes to working with a Notified Body, “You can benefit from building a relationship with your Notified Body and collaborating with them on various topics. Although MDR and IVDR have forced more stringent requirements that may hinder a consulting relationship, they’re usually willing to offer a certain level of guidance to help you.”

Choosing and working with an Notified Body is a critical step towards getting your product on the EU market, especially for new medical devices. Be sure to do your research before selecting an Notified Body, and communicate with them throughout the product realization phases to ensure your medical device is in compliance with MDR/IVDR requirements. Working successfully with a Notified Body is the best way to fast-track your medical device into one of the largest markets in the world. 

Read more about the general safety and performance requirements (GSPR) that Notified Bodies use as the basis for conformity assessments.

‍

‍

MedTech
Blogs

MedWatch: The FDA safety information and adverse event reporting program

By

Bethaney Lentz

September 29, 2022

4 min read

What is MedWatch?

What should you do if you encounter a serious side effect from a prescription drug you've taken? Or what if you were using a medical device and it malfunctioned and caused you serious harm? Do you contact the manufacturer, your doctor, or your local government? The quick answer is to contact the FDA, and it’s not as complex as you may think.

In the early 1990s, the FDA knew it needed a reliable way to help physicians, health care workers, and all those who work in the medical field to report adverse events related to pharmaceuticals and medical devices. An adverse event is any undesirable experience associated with the use of a medical product or pharmaceutical drug. They wanted a system that could be used to track these events and give them the insight they needed to review and track the reported issues. 

In 1993 the FDA introduced the MedWatch program designed to collect voluntary reports of adverse reactions and quality problems of drugs and medical devices, along with all other FDA-regulated products such as dietary supplements, cosmetics, pet food, toys, tobacco,  infant formulas, etc. The Stakeholder Engagement Staff within the office of the FDA commissioner is ultimately responsible for this program. They work closely with all FDA centers and offices across the entire agency and serve as a liaison between stakeholder organizations and the general public. In addition, it is their responsibility to report on medical product safety alerts, recalls, statements, and periodic safety labeling change summaries.

MedWatch is not only for medical professionals to report adverse events, but the public is also encouraged to report adverse events as well. And reporting an event to the FDA may be easier than you may think. 

MedWatch Reporting

When the FDA approves a medical drug or product, the agency has determined that the benefits of the product outweigh the risks. But, sometimes there are unforeseen risks that are discovered once a product or drug gets to market and people start using it. For example, a product may be used by a larger and more diverse group of people than was represented in the clinical testing. They may differ in the complexity of their health problems or other medications that they use. Because of these unanticipated events, the FDA encourages people to report problems they feel that they’ve experienced. 

To report a voluntary event online, you can use the MedWatch Online Voluntary Reporting Form 3500B, which is located on the FDA’s website. Form 3500B is a consumer-friendly reporting form that contains less technical language than the online FDA Form 3500, which is to be used by healthcare professionals. The form will step you through the process and should take about 15-20 minutes to complete. You can submit your contact information (in case they have questions or need clarification) or you can request that your information be kept confidential.

What happens after a report is made to MedWatch?

  • FDA staff enter the report into a database so that it is available for review and comparison to other reports.
  • An FDA safety evaluator, often a pharmacist, doctor, or nurse, reviews the report and examines the database for similar reports.
  • The FDA monitors the data for trends and investigates, if appropriate.
  • The FDA takes necessary action to protect public health.

Examples of FDA actions that could result from a report include:

  • issuing safety alerts with recommendations to monitor a product's use, adjust the way it is used, or stop using it
  • updating the product labeling to reflect new warnings
  • inspecting the manufacturer
  • requesting a change in the product’s design, manufacturing process, packaging, or distribution
  • requesting that a company recall a product

MedWatch is a safety tool for everyone to use. Every MedWatch report is important and is recorded in an FDA database for review and comparison to similar previous reports. Taken together, these reports can identify trends and signal safety problems, leading to an FDA action to protect the public. Remember, reporting can help you, a family member, or someone else avoid harm, serious illness, or even death. 

For more information, refer to the FAQ’s on the FDA website.

Join the MedWatch e-mail list here

‍

MedTech
Blogs

An overview of 21 CFR Part 820

By

Wendy Levine

September 23, 2022

4 min read

What is 21 CFR Part 820?

21 CFR 820 is the FDA federal regulation that pertains to quality systems for medical device manufacturers, and it is part of the agency’s set of Current Good Manufacturing Practices (CGMP) for industry. Also referred to as the FDA’s quality system regulation (QSR), the regulation defines design controls and quality processes at all stages of device development in order to ensure that all medical devices marketed in the United States are safe and effective.

21 CFR 820 consists of 15 subparts, which define quality system requirements for each stage and function within the medical device manufacturing process. We define each subpart below.

Federal regulations are organized as Title → Chapter → Subchapter → Part, which means that 21 CFR 820 is short-hand for:

21 CFR Part 820

21 CFR 820 vs ISO 13485

ISO 13485 is the de facto international quality system standard for medical device manufacturers, but this is not currently the standard in the United States. While Part 820 and ISO 13485 are structured differently, they have no conflicting requirements. Therefore, companies that are marketing medical devices in the U.S. and in other markets will need to comply with both ISO 13485 and the FDA’s QSR, as defined in 21 CFR 820. 

However, the FDA is moving towards harmonizing these standards, and on February 23, 2022 issued a proposed rule to amend the QSR to align more closely with the international consensus standard for Quality Management Systems, primarily by incorporating reference to the ISO 13485 standard. The FDA has published FAQ’s about the proposed rule.

21 CFR Part 820 Requirements

Part 820: General Controls (subpart A)

The General Controls subpart contains three sections providing general information about the regulation, including the scope and applicability along with key definitions.

Scope

The regulation defines current good manufacturing practice (CGMP) requirements governing the methods, facilities, and controls used for the “design, manufacture, packaging, labeling, storage, installation, and servicing of all finished devices intended for human use." Specifically, this subpart defines:

  • Applicability:

The requirements of this regulation are intended to ensure the safety and efficacy of all finished medical devices intended for human use that are manufactured in or imported into the United States. Manufacturers that are involved in some, but not all, manufacturing operations should comply with those requirements that are applicable to the functions they are performing. 

Exceptions:

  • This regulation does not apply to manufacturers of medical device components, but such manufacturers are encouraged to use this regulation as guidance.
  • Class I medical devices are exempt from the Design Controls defined in this regulation, except for those listed in § 820.30(a)(2). 
  • Manufacturers of blood and blood components are not subject to this regulation but are subject to Biologics good manufacturing practices as defined in Subchapter F, Part 606 of the regulation.

Definitions

This section of the regulation contains definitions for a number of terms used throughout the document. The following are the major definitions related to quality records:

  • Design history file (DHF): A compilation of records that describes the design history of a finished device.
  • Design input: The physical and performance requirements of a device that are used as a basis for device design.
  • Design output: The results of a design effort at each design phase and at the end of the total design effort. The finished design output is the basis for the device master record. The total finished design output consists of the device, its packaging and labeling, and the device master record.
  • Device history record (DHR): A compilation of records containing the production history of a finished device.
  • Device master record (DMR): A compilation of records containing the procedures and specifications for a finished device.

Quality System

The section of the regulation sets the basic requirement for a quality system by stating that “Each manufacturer shall establish and maintain a quality system that is appropriate for the specific medical device(s) designed or manufactured, and that meets the requirements of this part.” 

The term “appropriate” is used throughout this regulation and can be open to interpretation. A manufacturer, however, should assume that all requirements are appropriate and applicable except in cases where non-implementation of the requirement can be shown to have no effect on the product's specified requirements or ability to carry out necessary corrective actions.

Quality system requirements (subpart B)

This section of the regulation defines the overall responsibilities and the resources required for the management of the quality system.

Management responsibilities

Executive management is responsible for establishing a quality policy and ensuring adequate resources to effectively maintain and manage the quality system. In addition, management is responsible for establishing a specific quality plan, consisting of relevant practices, resources, activities, and procedures.

Quality audit

Periodic audits of the quality system are required to be conducted by personnel not directly responsible for the activities being audited. The dates and results of each audit need to be documented, along with the results of the audit. It is expected that corrective actions and, when necessary, reaudits, be performed for any identified noncompliances.

Personnel

Manufacturers are responsible for assigning sufficient personnel with appropriate experience and training to perform all tasks required by the quality system plan.

Design controls (subpart C)

Manufacturers of all class II and class III medical devices, along with the specific class I devices listed in paragraph (a)(2) of this regulation, are required to establish design control procedures that ensure design requirements are met as specified. 

Design controls shall define:

  • Design and development planning - Plans that describe the design and development activities, and responsibilities for these activities and their implementation.
  • Design input - Procedures that ensure design requirements are appropriate and address the intended use of the device.
  • Design output - Procedures that document design output, including acceptance criteria, so that conformance to design input requirements can be adequately evaluated.
  • Design review - Formal and documented reviews of the ensign results that include participation from representatives of all.
  • Design verification - Procedures for verifying the device design that confirm that the design output meets the design input requirements.
  • Design validation - Procedures for validating the device design, ensuring that devices conform to defined user needs and intended uses, and including testing of production units under actual or simulated conditions.
  • Design transfer - Procedures to ensure that the device design is correctly translated into production specification.
  • Design changes - Procedures for identifying, documenting, validating, and managing the verification and approval process of all design changes before they are implemented.
  • Design history file - A design history file (DHF) is required for each type of device and should include or reference the records necessary to demonstrate that the design was developed in accordance with the approved design plan and device requirements.

Document controls (subpart D)

Medical device manufacturers are required to put in place document controls for all documents required in this regulation.

Document approval and distribution

One or more people must be assigned to review and approve documents prior to issuance. The approval must be documented, include a date and the signature of the approver, and be made available at all locations where applicable. Procedures must also be in place to ensure that obsolete documents are removed and/or prevented from being used.

Document changes

Similar to document approval procedures, changes to documents must be approved, reviewed, and documented. Records of all changes must be maintained.

Purchasing controls (subpart E)

To continue reading this Regulatory Brief, including a definition of the remaining subparts and a comparison of 21 CFR 820 to ISO 13485, please download the full brief.

‍

MedTech
Blogs

What is the FDA eSTAR program?

By

Bethaney Lentz

September 22, 2022

4 min read

History

In September of 2018, the FDA took their first step in their commitment to improve the process of a 510(k) electronic submission. This commitment was established as part of the Food and Drug Administration Safety and Innovation Act (FDASIA) that was enacted on July 9, 2012, amending the FD&C Act by adding section 745A. 

Based on the FDA’s experience with the original eSubmitter process, the Center for Biologics Evaluation and Research (CBER) group piloted a slightly different program and called it the Electronic Submission Template and Resource Pilot Program, thus creating eSTAR. This second attempt at electronic submissions consists of a collection of questions, text, and prompts within a PDF template that guides a user to a ‘complete’ 510(k) electronic submission.

The FDA’s goal of this process is to enhance the quality of submissions by helping to ensure consistent, quality, comprehensive data for the Center for Disease and Radiological Health (CDRH) premarket review. With a standardized format in place, submitters of a 510(k) or De Novo can ensure that their submissions are complete and premarket reviews will be more efficient.

eSTAR timeline

FDA eSTAR timeline

eSTAR Requirements

Currently, eSTAR is a voluntary process that will become mandatory starting October 1, 2023. It is free to use by medical device applicants wishing to submit a 510(k) or a De Novo to the CDRH, but is not to be used for combination products. Although it’s currently free to use, the standard submission fees for 510(k) and De Novo still apply. 

A Refuse to Accept (RTA) review (a preliminary review used to ensure the submission is complete) will not be conducted on submitted eSTAR templates as the eSTAR template replaces this checklist and will state if the template is complete or incomplete on the first page. If the eSTAR does not have a completed status, it will not be reviewed by the FDA. 

Guidance Information

The FDA has provided final guidance documentation in “Providing Regulatory Submissions for Medical Devices in Electronic Format — Submissions Under Section 745A(b) of the Federal Food, Drug, and Cosmetic Act” (referred to as the “745A(b) device parent guidance”). This guidance document provides a  process for the development of templates to facilitate the preparation, submission, and review of regulatory submissions for medical devices solely in electronic format. 

The FDA then provided final guidance in “Electronic Submission Template for Medical Device 510(k) Submissions.” There are exemptions listed in the guidance document that may allow users in certain situations to be exempted from eSTAR. 

eSTAR Templates

The two templates provided by the FDA are PDF forms that can be filled out and saved, with attachments. The image below shows the device description page of the non-IVDR form. When using the form, red bars will appear in front of any required questions that have not yet been answered. Bars will turn green when all associated questions in a section have been completed. Gray bars indicate an optional question.

FDA eSTAR template

As questions are answered, additional dropdowns may appear that can require users to add additional information. For example, in the Pre-Submission Correspondence and Previous Regulatory Interaction Section within the non-IVD template, if you Select “Yes” the PDF will then add a section where you will need to add the Submission, Submission Number, and copies of the correspondence.

Pop-ups with useful information may also appear. For example, within the non-IVD template, in the General Device Characteristics Section, if a user selects that a device is a single use device, non-sterile or packaged as sterile, a Java Script window will appear with FDA guidance.

A note on embedded attachments: Any embedded attachments may only be used once per eSTAR PDF. You may need to “break up” documentation to fit the eSTAR template requirements if your testing reports cover multiple tests in one document. 

What’s involved in a submission?

There are currently two processes for submission:

  1. The Customer Collaboration Portal
  2. Mailing the eCopy (CD, DVD or USB drive) containing the eSTAR PDF

First, effective July, 2022, The Customer Collaboration Portal was made available to existing users of the portal if they are the official correspondent of an organization and have also received the FDA email letting them know that they’re eligible.

The second method consists of a printed cover letter with an accompanying eCopy (CD, DVD or USB drive) containing the eSTAR PDF. Note that if the PDF submission exceeds 1 GB in size, it could delay the process, so high-resolution videos and images should only be included when necessary.

  • Download the specific eSTAR PDF template for an In Vitro or Non-In Vitro device (see "Current eSTAR versions" section on this linked page).
  • Fill out the template accordingly but note that it is only used for constructing - not submitting - your submission.
  • The eSTAR does not need to comply with the FDA’s eCopy Guidance document, however, any additional files that are provided with the eSTAR PDF submission will need to comply with it. The FDA strongly recommends not providing additional files with the eSTAR PDF, though, as you already will be embedding your documents within the eSTAR template itself.
  • You do not need to provide an Indications for Use page, the Premarket Review Submission Cover Sheet, or a Declaration of Conformity (if applicable) with your submission since they are already built into the eSTAR PDF. An additional option is to also build the 510(k) summary within the template itself instead of writing one. 

An eSTAR submission will contain a larger number of files (as they will be embedded in the PDF eSTAR template) than traditional submissions, which are usually combined into one PDF file. We recommend preparing your entire submission before filling out the eSTAR template to minimize the need for reworking the submission.

A note on 510(k) product change submissions: The eSTAR template requires that all subsections be completed, so if you are submitting a 510(k) to address a product change, you will want to include a justification for not including original information in required sections that did not change. Otherwise, all submitted information will be reviewed again, even if it does not differ from the original submission.

Review Timeline

The review timeline will be similar to the review timeline for a non-electronic submission for a 510(k). The guidance document “The 501(k) Program: Evaluating Substantial Equivalence in Premarket Notification  [510(k)]” can offer more details. The same would apply for the De Novo in that you would need to reference the guidance document “De Novo Classification Process (Evaluation of Automatic Class III Designation)” for review timelines. 

Tracking the Submission

The FDA secures the information about each submission’s progress so only its Official Correspondent (your company’s submission representative) can view it. You will be able to track the progress of your submission by using the Customer Collaboration Portal (CCP).

  • If this is your Official Correspondent’s first time tracking a submission online, the FDA will automatically email a link to create a login password soon after the FDA starts its review.
  • The FDA currently displays progress online for Traditional, Abbreviated, and Special 510(k) submissions.
  • The FDA will formally notify you of your submission’s status by emailing your Official Correspondent with official actions and requests.

The future of eSTAR

These efforts are part of the FDA’s ongoing commitment to work with the industry and to improve the efficiency of the medical device review process. The final guidance for the 510(k) eSTAR was published this month and will become effective October 1, 2023, for 510(k) and De Novo submissions. In the long term if MUDUFA V is passed with the current requests from the FDA, the process will become a required standard for additional submission types such a PMA and will replace the need to mail eCopies containing eSTAR files through the FDA Collaboration Portal.

‍

MedTech
I agree to the privacy policy including to Rimsys using my contact details to contact me for marketing purposes.
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Hand holding smartphone showing email app with 12 unread messages notification.